48XX/49XXSHB0399
7.5
Additional function blocks
7.5.1
Process controller
Description
The process controller is designed as independent function block and is a PID
controller with a cycle time of 12 ms.
It can for instance be used as superimposed controller (dancer position control,
tension control, etc.).
4900Str053
S e t
A c t .
O u t p u t
E v a l u a t i o n
I - c o m p o n e n t
s w i t c h - o f f
D e a c t i v a t i o n
p r o c e s s c o n t r o l l e r
S u p p r e s s i o n
p r o c e s s c o n t r o l l e r
FIG 7-26
Process controller
Features
( P adaptation possible via an internal function (derived from set-value) or
external analog signal source; enable adaptation with C329 = -1-
( Ramp function generator in set-value channel
( Overlay of process controller output over ramp function generator
( Intregral action component to be switched-off via freely assignable digital
terminal (I component = 0)
( Deactivation of the process controller via freely assignable digitale terminal (I
component = 0, output = 0)
( Suppression of the process controller output via freely assignable digital
terminal (output = 0 after time C335)