Configuration – Lenze EDS4900U-REG User Manual
Page 228

Configuration
7-137
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C231*
Min. field
current
100%
10 % I
Frated
{1% I
Frated
} 100% I
Frated
Reference: I
Frated
(C083), observe min.
value under C083!
C232*
I
¼R
compensation
0.0%
0.0 % V
rated
{0.1% V
rated
} + 30 % V
rated
Reference: V
rated
(C090)
C233*
V
p
-V
ab
controller
1.0
0.1
{0.1}
10
10
{1.0}
50
Gain of the V
ab
controller
[C234*] T
n
-V
ab
controller 400 ms 20 ms
{10 ms}
2000 ms
9999 ms
T
n
= 9999 ms: I-component switched-off
(only when controller is inhibited)
[C235*] Excitation
characteristic
0
-0-
internal excitation characteristic active
-1-
internal excitation characteristic not active
With C253= -1-, the control process is
based on operation with rated excitation
[C237*] Synchronisation
mode
0
-0-
dyn. IMP, 20 ms correction
-1-
no dyn. IMP, 20 ms correction
-2-
dyn. IMP, 400 ms correction
-3-
no dyn. IMP, 400 ms correction
C240*
Window
n
act
= n
set
1%
0 % n
max
{0.1% n
max
} + 100% n
max
Threshold for n
act
= n
set
, reference: n
max
C241
Window
RFG on =
RFG off
1%
0 % n
max
{0.1% n
max
} + 100% n
max
Threshold ramp function generator input
= ramp function generator output,
reference: n
max
C242*
Threshold
|
n
act
|
n
x
1000
rpm
100 rpm
{1 rpm}
5000rpm
C243*
Threshold
n
set
> n
x
1%
0 % n
max
{0.1 % n
max}
+ 100 % n
max
Threshold for
'C046| or'C049| > n
x
, reference: n
max
C244*
Threshold
'I
A
|> I
x
10%
0 % I
Amax
{0.1% I
Amax
} + 100 % I
Amax
'I
A|
> I
x
Reference, rated controller current
(armature)
C245*
Threshold
I
F
> I
x
10%
0 % I
Fmax
{0.1% I
Fmax
} + 100% I
Fmax
I
F
> I
x ,
Reference, rated controller current (field)
C249*
¤ LECOM1 code
bank
1
0
{1}
7
Fixed address offset:
LECOM1 interface (protocol LECOM A/B)
can address codes > 255.
C252*
Angle offset
0 inc
-245760000 inc
{1 inc}
245760000 inc
Fixed angle offset with digital frequency
configurations (C005 = -5X-, -6X-, -72-)
Format for LECOM: 0.022 (LECOM)
correspond to 220 incr.
C253*
Angle offset
0 inc
-8190 inc
{1}
8190 inc
Speed-dependent angle offset
Format for LECOM: 0.022 (LECOM)
correspond to 220 incr.
C254*
V
p
angle
controller
0.33
0.00
{0.01}
1.00
Gain of the angle controller
C255*
Following error
limit
220 inc 10 inc
{1 inc}
536750000 inc
Only active if C254 > 0!
Format for LECOM: 0.022 (LECOM)
correspond to 220 incr.
C256*
Angle trimming
0 inc
-32768 inc
{1 inc}
32767 inc
Angle offset with digital frequency con-
figurations (C005 = -5X-, -6X- and -72-)
Format for LECOM: 0.022 (LECOM)
correspond to 220 incr. If an analog signal
source (C145/C146) is assigned, the
parameter will be displayed only.
Show/Hide Bookmarks