10 table of attributes, Configuration – Lenze EDS4900U-REG User Manual
Page 236

Configuration
7-145
48XX/49XXSHB0399
7.10
Table of attributes
The information given in this attribute table is required for generating a
programmme. It contains all information about the communication to the controller
via parameters:
Column
Meaning
Entry
Code
Name of the Lenze codes
Cxxxx
Index
dec
Index, under which the parameter
is defined.
24575
Lenze code
number
Is only required for control via
InterBus or PROFIBUS.
hex
The subindex of array variables
corresponds to the Lenze
subcode number.
5FFh
Lenze code
number
InterBus or PROFIBUS.
Data
DS
Data structure
E
Simple variable (one parameter value)
Data
DS
Data structure
A
Array variable (several parameter
elements can be selected through the
code for input selection or via LECOM
subcode)
I
Image variable (several parameter
elements can be selected through the
code for input selection).
DA
Number of array elements
(Subcodes)
xx
DT
Data type
B8
1 byte bit coded
DT
Data type
B16
2 byte bit coded
FIX32
32 bit value with sign; decimal with
four decimal codes
Example:
1 2
12000
FIX32 dec
1.2
12000
FIX32-dec
00002EEO
FIX32-hex
-10.45
-104500
FIX32-dec
FFFE67CC
FIX32-hex
I16
2 byte with sign
(-32768
$ X $ 32767)
I32
4 byte with sign
(-2147483648
$X $2147483647)
N16
16 bit value with sign
0%
0; 100% 2
14
Example:
100%
16384
N16-dec
4000
N16-hex
-50%
-8192
N16-dec
E000
N16-hex
U16
2 byte without sign
( 0
$X $ 65535)
VS
ASCII string
format
LECOM format
VD
ASCII decimal format
format
LECOM format
(see Operating Instructions for
VH
ASCII hexadecimal format
(see Operating Instructions for
fieldbus modules)
VS
String format
DL
Data length in byte
Access
P/S
Parameter setting / control
P
Parameter setting
Access
P/S
Parameter setting / control
(according to C001)
S
Control
LCM-R/W
Access authorization for LECOM
Ra
Reading is always permitted
LCM R/W
Access authorization for LECOM
Wa
Writing is always permitted
W
Writing depends on condition
AIF
Proceß datum in automation
interface
Mapping to LECOM2 process
data channel possible
PZD
Process datum
Show/Hide Bookmarks