Configuration – Lenze EDS4900U-REG User Manual
Page 94

Configuration
7-3
48XX/49XXSHB0399
Code
Name
Possible settings
Code
Name
Lenze Selection
Info
C038
¤ Input
preselection:
JOG
set-value
1
-1-
Selection JOG1
-2-
Selection JOG2
...
-15-
Selection JOG15
Select JOG setpoint to be set under C039.
C039
JOG speed
for C038
-100 % n
max
{0.1 %}
+ 100.0 % n
max
100.0%
JOG1
75.0%
JOG2
50.0%
JOG3
25.0%
JOG4
0.0 %
JOG5
..
...
0.0 %
JOG15
Enable JOG set-values via the digital
inputs or via C045.
Assignment of the digital inputs
The number of inputs to be assigned with the function ”enable JOG set-value”,
depends on the number of JOG set-values required.
Number of JOG set-values required
Number of inputs required
1
at least 1
2...3
at least 2
4...7
at least 3
8...15
4
This function can be assigned to up to four inputs.
For input assignment, observe the notes in chapter 5.6.
JOG set-value enabling with terminal control
The assigned digital inputs must be controlled according to the table below to
enable JOG set-values.
2. input
3. input
4. input
JOG 1
1
0
0
0
JOG 2
0
1
0
0
JOG 3
1
1
0
0
JOG 4
0
0
1
0
JOG 5
1
0
1
0
JOG 6
0
1
1
0
JOG 7
1
1
1
0
JOG 8
0
0
0
1
JOG 9
1
0
0
1
JOG 10
0
1
0
1
JOG 11
1
1
0
1
JOG 12
0
0
1
1
JOG 13
1
0
1
1
JOG 14
0
1
1
1
JOG 15
1
1
1
1
The input with the lowest figure is the first input, the input with the next higher figure
is the second input, and so on (e. g. E4 = 1. input, E5 = 2. input).
C045 indicates the active set-value.