Configuration – Lenze EDS4900U-REG User Manual
Page 212

Configuration
7-121
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C011
n
max
speed
3000
rpm
250 rpm
{1rpm}
5000 rpm
n
max
is the reference for the analog and
relative setpoint selection as well as for
the acceleration and deceleration times.
Parameter setting via interface:
Inhibit the controller before substantial
parameters changes.
C012
Acceleration
time T
ir
for main
setpoint
0.00s
0.00 s
{0.01 s}
1 s
1 s
{0.1 s}
10 s
10 s
{1 s}
100 s
100 s
{10 s}
990 s
Time refers to 0...n
max
C013
Deceleration
time T
if
for main
setpoint
0.00s
0.00 s
{0.01 s}
1 s
1 s
{0.1 s}
10 s
10 s
{1 s}
100 s
100 s
{10 s}
990 s
Time refers to 0...n
max
C017*
Threshold
n
act
n
x
-3000
rpm
-5000 rpm
{1 rpm}
+ 5000 rpm
If the actual speed falls below the
comparison speed n
x
, the corresponding
output will be activated.
C019*
Threshold
n
act
= 0
50 rpm 0 rpm
{1 rpm}
5000 rpm
If the actual speed falls below the
threshold, the corresponding output will
be activated.
C022
+ I
max
limit
Rated
control-
ler cur-
rent
Current limit of thyrister bridge 1
0
{0.1A}
100A
100A
{1A}
1200A
Current limit depends on controller:
29A
(4902)
45A
(4903)
90A
(4904)
150A (4905)
240A (4906)
C023
-I
max
limit
Current limit of thyrister bridge 2
0
{0.1A}
100A
100A
{1A}
1200A
(
)
300A (4907)
400A (4X08)
600A (4X09)
840A (4X11)
1200A (4X12)
1350A (4X13)
C025
¤ Input selection:
Input
adjustment
2
-1-
Terminals X1/1, X1/2
-2-
Terminals X1/3, X1/4
-3-
Terminal X1/6
-4-
Terminal X1/8
-5-
Armature voltage feedback
-10
Digital frequency input X5
-11-
Digital frequency input X9
-12-
Resolver X7
-13-
Encoder output X8
Select (under C025) the input which is to
be adjusted with C026, C027, C028 or
C029.