Configuration – Lenze EDS4900U-REG User Manual
Page 233

Configuration
7-142
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C590*
Input 1,
comparator 2
0 %
-100.0 %
{0.1 %}
+ 100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, only the parameter will be
displayed.
C591*
Input 2,
limit value for
comparator 2
0 %
-100.0 %
{0.1 %}
+ 100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, only the parameter will be
displayed.
C592*
Hysteresis for
lower threshold
comparator 2
0 %
0.0 %
{0.1 %}
+ 100.0 %
Lower threshold = C591 - C592,
reference: C591
C593*
¤ Memory
function
comparator 2
-0-
Memory function not active
when resetting the output, the value falls
below the lower threshold (C591 - C592)
-1-
Memory function active
The output remains set after inital switching
on.
C594*
¤ Reset function
comparator 2
-0-
Reset function not active
-1-
Reset function active
The activation resets the output.
C600*
¤ Arithmetic
block 3
1
-0-
Output = C601
-1-
Output = C601 + C602
-2-
Output = C601 - C602
-3-
Output = C601
¼ C602
-4-
Output = C601 / |C602|
-5-
Output = C601 / (100% - C602)
C601*
Input 1,
arithmetic
block 3
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C602*
Input 2,
arithmetic
block 3
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1%}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.