Scope of supply, Connections and interfaces, Status displays – Lenze ECSCMxxx User Manual
Page 4

l
4
EDBCSXM064 EN 11.0
Scope of supply
Position
Description
Quantity
A
ECS
LM... axis module
1
Accessory kit with fixing material corresponding to the design (
L):
l
"E" − standard panel−mounted unit
l
"D" − push−through technique
l
"C" − cold−plate technique
1
Mounting Instructions
1
Drilling jig
1
Functional earth conductor (only ECSDM...)
1
)
Note!
The ECSZA000X0B connector set must be ordered separately.
Connections and interfaces
Position
Description
Detailed
information
X23
Connections
l
DC−bus voltage
l
PE
^ 54
B
LEDs: Status and fault display
X1
Automation interface (AIF) for
l
Communication module
l
Operating module (keypad XT)
^ 79
^ 191
x2
PE connection of AIF
X3
Analog input configuration
^ 69
X4
CAN connection
l
MotionBus (CAN) / for ECSxA: System bus (CAN)
l
Interface to the master control
^ 80
X14
CAN−AUXconnection
l
System bus (CAN)
l
PC interface/HMI for parameter setting and diagnostics
X6
Connections
l
Low−voltage supply
l
Digital inputs and outputs
l
Analog input
l
"Safe torque off" (formerly "safe standstill")
^ 64
^ 68
^ 69
^ 70
S1
DIP switch
l
CAN node address
l
CAN baud rate
^ 197
X7
Resolver connection
^ 86
X8
Encoder connection
l
Incremental encoder (TTL encoder)
l
Sin/cos encoder
^ 87
X25
Brake control connection
^ 61
X24
Motor connection
^ 60
Status displays
LED
Operating state
Check
Red
Green
Off
On
Controller enabled, no fault
Off
Blinking
Controller inhibited (CINH), switch−on inhibit
Code C0183
Blinking
Off
Fault/error (TRIP) active
Code C0168/1
Blinking
On
Warning/FAIL−QSP active
Code C0168/1