Technical data

Current characteristics

Device protection by current derating

3

l

37

EDBCSXM064 EN 11.0

3.3.2

Device protection by current derating

The maximum output current is limited. With output frequencies < 5 Hz the limitation
depends on the heatsink temperature.

0.75

1.00

0.57

0.38

0.67

0.00

1.00

0

5

10

fout [Hz]

Iout
Imax

≤ 70 °C

90 °C



ƒ

‚

ECSXA024

Fig. 3−2

Current derating characteristics



Operation with switching frequency = 8 kHz (C0018 = 1).

l

If the current exceeds the characteristic

, the switching frequency is automatically

changed to 4 kHz (e.g. for higher torque in acceleration processes).

‚

Operation with switching frequency = 4 kHz (C0018 = 0).

l

The current limitation follows the characteristic

‚.

l

With output frequencies < 5 Hz and heatsink temperatures between 70 and 90 °C the
current limit is steplessly adjusted in the range

ƒ.

Type

I

max

[A]

Switching frequency 8 kHz



Switching frequency 4 kHz

‚

f

out

> 5 Hz

f

out

W 0 Hz

f

out

> 5 Hz

f

out

W 0 Hz

£ 70 °C

f

out

W 0 Hz

90 °C

ECSxM004

2.7

1.5

4.0

3.0

2.3

ECSxM008

5.3

3.0

8.0

6.0

4.6

ECSxM016

10.7

6.0

16.0

12.0

9.1

ECSxM032

21.3

12.1

32.0

24.0

18.1

ECSxM048

32.0

18.1

48.0

36.3

27.2

ECSxM064

42.7

24.2

64.0

48.0

36.3