9300 servo plc, Ȧȧ ȡ ȣ, Ȧȧ ȣ ȥ – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 83: System blocks, Forced ventilated or naturally ventilated motors
9300 Servo PLC
System blocks
2.12
MCTRL_MotorControl (node number 131)
2−77
L
9300 Servo PLC EN 5.1
Forced ventilated or naturally ventilated motors
Parameter setting
The following codes can be set for I
2
x t monitoring:
Code
Meaning
Value range
Lenze setting
C0066
Display of the I
2
x t load of the motor
0 ... 250 %
−
C0120
Threshold: Triggering of error "OC6"
0 ... 120 %
0 %
C0127
Threshold: Triggering of error "OC8"
0 ... 120 %
0 %
C0128
Thermal motor time constant
0.1 ... 50.0 min
5.0 min
C0606
Response to error "OC8"
TRIP, warning, off
Warning
Calculate release time and I
2
x t load
Formula for release time
Information
t
+ * ( t ) ln
ȧȧ
ȡ
Ȣ
1
*
z
) 1
ǒ
I
Mot
I
N
Ǔ
2
100
ȧȧ
ȣ
Ȥ
I
Mot
Actual motor current (C0054)
I
r
Rated motor current (C0088)
t
Thermal motor time constant (C0128)
z
Threshold value in C0120 (OC6) or C0127 (OC8)
Formulae for I
2
x t load
Information
L(t)
+
ǒ
I
Mot
I
N
Ǔ
2
100%
ǒ
1
* e
*t
t
Ǔ
L(t)
Chronological sequence of the I
2
x t load of the motor
(Display: C0066)
I
Mot
Actual motor current (C0054)
Ir
Rated motor current (C0088)
t
Thermal motor time constant (C0128)
If the controller is inhibited, the I
2
x t load is reduced:
L(t)
+ L
Start
e
*
t
t
Ǹ
L
Start
I
2
x t load before controller inhibit
If an error is triggered, the value corresponds to the threshold value set
in C0120 (OC6) or C0127 (OC8).
Read release time in the diagram
Diagram for detecting the release times for a motor with a thermal motor time constant of 5 minutes
(Lenze setting C0128):
I
= 3 × I
Mot
N
0
50
100
120
0
100
200
300
400
500
600
700
800
900
1000
t [s]
L [%]
I
= 2 × I
Mot
N
I
= 1.5 × I
Mot
N
I
= 1 × I
Mot
N
9300STD105
Fig. 2−28
I
2
× t−monitoring: Release times for different motor currents and trigger thresholds
I
Mot
Actual motor current (C0054)
I
r
Rated motor current (C0088)
L
I
2
x t load of the motor (display: C0066)
T
Time