2.12

MCTRL_MotorControl (node number 131)

9300 Servo PLC

System blocks

2−58

L

9300 Servo PLC EN 5.1

2.12.5

Torque limitation

Via MCTRL_nLoMLim_a and MCTRL_nHiMLim_a you can set an external torque limitation. This
means that different torques can be selected for the quadrants "driving" and "braking".

·

MCTRL_nHiMLim_a is the upper torque limit in [%] of the max. possible torque.

·

MCTRL_nLoMLim_a is the lower torque limit in [%] of the max. possible torque.

·

The max. possible torque is set under C0057.

(

^ 2−57)

Stop!

Only set positive values in MCTRL_nHiMLim_a and negative values in MCTRL_nLoMLim_a,
otherwise the speed controller may be unable to perform its intended control function. This can result
in an uncontrolled acceleration of the drive.

Tip!

·

If MCTRL_nHiMLim_a is not assigned (free), the upper torque limit automatically is 100 % of
the max. possible torque.

·

If MCTRL_nLoMLim_a is not assigned (free), the lower torque limit automatically is −100 % of
the max. possible torque.

·

At quick stop (QSP) the torque limitation is deactivated, i.e. the drive is operated with

±

100 %.