9300 servo plc, Appendix – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 157
9300 Servo PLC
Appendix
3−151
L
9300 Servo PLC EN 5.1
Parameters
Code
Data type
Access Info
Subcode
Possible settings
Presetting
C0504
−
R / W
Activate/deactivate write protection for RAM
·
When the write protection is activated, the RAM cannot be written via
LenzeMemDrv.lib codes or functions.
1
0 Deactivate write protection for RAM block 1
0
1 Activate write protection for RAM block 1
2
0 Deactivate write protection for RAM block 2
0
1 Activate write protection for RAM block 2
C0505
−
W
Offset address within the RAM block selected under C0506
0
{1}
65532 0
C0506
−
W
Selection of the RAM block for access under C0508/C0509
1 RAM block 1
2 RAM block 2
C0507
Double integer
R
Value read from the RAM block
·
After the RAM block has been read, the pointer to the memory address is
automatically incremented by 4 bytes.
C0508
Double integer
W
Value to be written in the RAM block
·
After the RAM block has been written, the pointer to the memory address is
automatically incremented by 4 bytes.
C0509
−
R / W
Check sum test
Note: Stop the PLC during the check sum test to avoid a time−out when reading
back the code.
0 Deactivated
0
1 Activated
Note!
·
The RAM access is processed in parallel to the PLC program in the system task. The
processing time therefore depends on the workload of the system.
·
You can use the functions of the LenzeMemDrv.lib function library to access the RAM from
your IEC 61131 program.