beautypg.com

9300 servo plc, Appendix – Lenze DDS Target 9300 Servo PLC V8.x User Manual

Page 157

background image

9300 Servo PLC

Appendix

3−151

L

9300 Servo PLC EN 5.1

Parameters

Code

Data type

Access Info

Subcode

Possible settings

Presetting

C0504

R / W

Activate/deactivate write protection for RAM

·

When the write protection is activated, the RAM cannot be written via
LenzeMemDrv.lib codes or functions.

1

0 Deactivate write protection for RAM block 1

0

1 Activate write protection for RAM block 1

2

0 Deactivate write protection for RAM block 2

0

1 Activate write protection for RAM block 2

C0505

W

Offset address within the RAM block selected under C0506

0

{1}

65532 0

C0506

W

Selection of the RAM block for access under C0508/C0509

1 RAM block 1

2 RAM block 2

C0507

Double integer

R

Value read from the RAM block

·

After the RAM block has been read, the pointer to the memory address is
automatically incremented by 4 bytes.

C0508

Double integer

W

Value to be written in the RAM block

·

After the RAM block has been written, the pointer to the memory address is
automatically incremented by 4 bytes.

C0509

R / W

Check sum test
Note: Stop the PLC during the check sum test to avoid a time−out when reading
back the code.

0 Deactivated

0

1 Activated

Note!

·

The RAM access is processed in parallel to the PLC program in the system task. The
processing time therefore depends on the workload of the system.

·

You can use the functions of the LenzeMemDrv.lib function library to access the RAM from
your IEC 61131 program.