Outputs_aif_management, 9300 servo plc, System blocks – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 31: 2 outputs_aif_management
![background image](/manuals/566017/31/background.png)
9300 Servo PLC
System blocks
2.4
AIF_IO_Management (node number 161)
2−25
L
9300 Servo PLC EN 5.1
2.4.2
Outputs_AIF_Management
This SB transfers commands and messages to a fieldbus module connected to an automation
interface (AIF).
For this purpose C2120 provides a control word. The commands are specified as numbers. Some
command numbers are universally applicable for all fieldbus modules, others apply only for special
modules. The total number of commands available can amount to up to 16.
Tip!
Read the documentation for the attached fieldbus module.
Bit 7
Toggle-Bit (MSB)
Bit 8 … 15
AIF control word
Outputs_AIF_Management
AIF_wControl
C2120
Bit 0 … 6
Fig. 2−8
System block "Outputs_AIF_Management"
System variables
Variable
Data type
Signal type
Address
Display code
Display
format
Note
AIF_wControl
Word
%QX161.0
C2120
Codes
Code
LCD
Possible settings
Info
Lenze
Selection
C2120 AIF: Control
AIF command
0
No command
1
Read CAN codes + reinitialisation
2
Read XCAN codes
10
Read XCAN C2356/1 ... 4
11
Read XCAN C2357
12
Read XCAN C2375
13
Read XCAN C2376 ... C2378
14
Read XCAN C2382
255
Not assigned