9300 servo plc, Appendix, 6 code table – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 132
3.6
Code table
9300 Servo PLC
Appendix
3−126
L
9300 Servo PLC EN 5.1
Code
Information
Possible settings
LCD
Code
Information
Selection
Lenze
LCD
[C0086] Mot type
Lenze inverter motor in star connection
·
Temperature monitoring via resolver or encoder cable
is automatically deactivated, i.e.:
C0583 = 3
C0584 = 3
C0594 = 3
210
DXRA071−12−50
211
DXRA071−22−50
212
DXRA080−12−50
214
DXRA090−12−50
215
DXRA090−32−50
216
DXRA100−22−50
217
DXRA100−32−50
218
DXRA112−12−50
219
DXRA132−12−50
220
DXRA132−22−50
221
DXRA160−12−50
222
DXRA160−22−50
223
DXRA180−12−50
224
DXRA180−22−50
DXRAXX071−12, f
d
: 50Hz
DXRAXX071−22, f
d
: 50Hz
DXRAXX080−12, f
d
: 50Hz
DXRAXX090−12, f
d
: 50Hz
DXRAXX090−32, f
d
: 50Hz
DXRAXX100−22, f
d
: 50Hz
DXRAXX100−32, f
d
: 50Hz
DXRAXX112−12, f
d
: 50Hz
DXRAXX132−12, f
d
: 50Hz
DXRAXX132−22, f
d
: 50Hz
DXRAXX160−12, f
d
: 50Hz
DXRAXX160−22, f
d
: 50Hz
DXRAXX180−12, f
d
: 50Hz
DXRAXX180−22, f
d
: 50Hz
225
30kW−ASM−50
226
37kW−ASM−50
227
45kW−ASM−50
228
55kW−ASM−50
229
75kW−ASM−50
Lenze inverter motor in delta connection
·
Temperature monitoring via resolver or encoder cable
is automatically deactivated, i.e.:
C0583 = 3
C0584 = 3
C0594 = 3
250
DXRA071−12−87
251
DXRA071−22−87
252
DXRA080−12−87
254
DXRA090−12−87
255
DXRA090−32−87
256
DXRA100−22−87
257
DXRA100−32−87
258
DXRA112−12−87
259
DXRA132−12−87
260
DXRA132−22−87
261
DXRA160−12−87
262
DXRA160−22−87
263
DXRA180−12−87
264
DXRA180−22−87
DXRAXX071−12, f
d
: 87Hz
DXRAXX071−22, f
d
: 87Hz
DXRAXX080−12, f
d
: 87Hz
DXRAXX090−12, f
d
: 87Hz
DXRAXX090−32, f
d
: 87Hz
DXRAXX100−22, f
d
: 87Hz
DXRAXX100−32, f
d
: 87Hz
DXRAXX112−12, f
d
: 87Hz
DXRAXX132−12, f
d
: 87Hz
DXRAXX132−22, f
d
: 87Hz
DXRAXX160−12, f
d
: 87Hz
DXRAXX160−22, f
d
: 87Hz
DXRAXX180−12, f
d
: 87Hz
DXRAXX180−22, f
d
: 87Hz
265
30kW−ASM−87
266
37kW−ASM−87
267
45kW−ASM−87
268
55kW−ASM−87
269
75kW−ASM−87
[C0087] Mot speed
à
Rated motor speed
à
Dependent on C0086
·
If C0086 is changed, the value is reset to the assigned
Lenze setting.
·
Change sets C0086 = 0.
300
{1 rpm}
16000
[C0088] Mot current
à
Rated motor current
à
Dependent on C0086
·
If C0086 is changed, the value is reset to the assigned
Lenze setting.
·
Change sets C0086 = 0.
0.5
{0.1 A}
500.0