Outputs_digital (digital outputs), 9300 servo plc, System blocks – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 54: 2 outputs_digital (digital outputs), 10 digital_io (node number 1), System variables, Electrical data of the output terminals
2.10
DIGITAL_IO (node number 1)
9300 Servo PLC
System blocks
2−48
L
9300 Servo PLC EN 5.1
2.10.2
Outputs_DIGITAL (digital outputs)
This SB conditions the digital signals and outputs them at terminals X5/A1 ... A4.
X5
Outputs_DIGITAL
1
0
C0118/1...4
A3
A1
A4
A2
1
DIGOUT_bOut1_b
DIGOUT_bOut4_b
DIGOUT_bOut3_b
DIGOUT_bOut2_b
C0444/1...4
Fig. 2−22
Outputs_DIGITAL
System variables
Variable
Data type
Signal type
Address
Display
code
Display
format
Note
DIGOUT_bOut1_b
Bool
Binary
%QX1.0.0
C0444/1
bin
DIGOUT_bOut2_b
%QX1.0.1
C0444/2
DIGOUT_bOut3_b
%QX1.0.2
C0444/3
DIGOUT_bOut4_b
%QX1.0.3
C0444/4
Electrical data of the output terminals
Terminal
Use
Measuring range
X5/A1
Freely assignable
LOW level:
HIGH level:
Output current:
Delay times:
0 ... +4 V
+13 ... +30 V
Max. 50 mA per output
(external resistance
³480 W at 24 V)
300
ms with rising edge
100
ms with falling edge
X5/A2
X5/A3
X5/A4
X5/39
Ground (GND) of digital inputs and outputs
·
The terminal polarity of the outputs X5/A1 ... A4 can be configured under C0118:
Code
LCD
Possible settings
Info
Lenze
Selection
C0118 DIGOUT pol
Terminal polarity
0
HIGH active
1
LOW active
1
0
X5/A1
2
0
X5/A2
3
0
X5/A3
4
0
X5/A4