9300 servo plc, Appendix, 6 code table – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 148
3.6
Code table
9300 Servo PLC
Appendix
3−142
L
9300 Servo PLC EN 5.1
Code
Information
Possible settings
LCD
Code
Information
Selection
Lenze
LCD
C0603 MONIT CE5
3
System bus: Monitoring configuration
Time−out when remote parameterisation is activated
(C0370)
0
TRIP
2
Warning
3
Off
C0606 MONIT OC8
2
Configuration of the I
2
× t−advance warning
The threshold is set in C0127.
0
TRIP
2
Warning
3
Off
C0608 ovr Tx−Queue
0
System bus: Monitoring configuration
Free CAN objects: Tx buffer (transmission memory
overflow)
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP
C0609 over Rx−lsr
0
System bus: Monitoring configuration
Free CAN objects: Too many telegrams received
0
TRIP
4
FAIL−QSP
C0855 DIS: IN (0−15)
g
Automation interface (AIF): Process data input words
0000
{hex}
FFFF
Hexadecimal value is bit−coded:
1
Bit 00
AIF1_bInB0_b
Bit 01
AIF1_bInB1_b
...
Bit 15
AIF1_bInB15_b
AIF1_IN: Process data input word 3
2
Bit 00
AIF1_bInB16_b
Bit 01
AIF1_bInB17_b
...
Bit 15
AIF1_bInB31_b
AIF1_IN: Process data input word 4
C0856 DIS: IN.Wx
g
Automation interface (AIF): Process data input words
−32768
{1 %}
32767
1
AIF1_IN: Process data input word 2 (AIF1_nInW1_a)
2
AIF1_IN: Process data input word 3 (AIF1_nInW2_a)
3
AIF1_IN: Process data input word 4 (AIF1_nInW3_a)
C0857 DIS: IN.D1
g
Automation interface (AIF): Process data input word
·
AIF1_dnInD1_p (32−bit angle information)
−2147483648
{1}
2147483647
C0858 DIS: OUT.Wx
g
Automation interface (AIF): Process data output words
−32768
{1 %}
32767
1
AIF1_OUT: Process data output word 2 (AIF1_nOutW1_a)
2
AIF1_OUT: Process data output word 3 (AIF1_nOutW2_a)
3
AIF1_OUT: Process data output word 4 (AIF1_nOutW3_a)
C0859 DIS: OUT.D1
g
Automation interface (AIF): Process data output word
·
AIF1_dnOutD1_p (32−bit phase information)
−2147483648
{1}
2147483647