2.8
DFIN_IO_DigitalFrequency (node number 21)
9300 Servo PLC
System blocks
2−36
L
9300 Servo PLC EN 5.1
2.8
DFIN_IO_DigitalFrequency (node number 21)
2.8.1
Inputs_DFIN
This SB can convert a pulse current at the digital frequency input X9 into a speed value and scale it.
·
The transmission is very precise without offset and gain errors.
·
In addition, this SB provides the phase correction value DFIN_dnIncLastScan_p which is
required within the calling task for phase processing of touch probe processes.
(
DFIN_IO_DigitalFrequency
C0426
X9
C0425
1
0
TP/MP
-Ctrl
C0428
C0429
DFIN_nIn_v
DFIN_bTPReceived_b
DFIN_dnIncLastScan_p
MP
DFIN_bEncFaultCable_b
C0427
4V
(X9/8)
MONIT_SD3
E5
C0431
0
1
Fig. 2−15
DFIN_IO_DigitalFrequency
System variables
Variable
Data type
Signal type
Address
Display
Code
Display
Format
Note
DFIN_nIn_v
Integer
Velocity
%IW21.0
C0426
dec [rpm]
Value in inc/ms
DFIN_bEncFaultCable_b
Bool
Binary
%IX21.1.0
−
−
TRUE = Monitoring
"FaultEncCable" has been
triggered because X9/8 is not
supplied with voltage and the
digital frequency coupling is thus
interrupted.
DFIN_bTPReceived_b
Bool
Binary
%IX21.1.2
−
−
Receive touch probe (TP)
DFIN_dnIncLastScan_p
Double integer
Position
%ID21.1
−
−
Dinc between TP and task start
Stop!
The digital frequency input X9 cannot be used if
·
you use the digital frequency output X10 (C0540 = 0, 1, 2) and
·
an incremental encoder/sin−cos encoder!