Outputs_analog1 (analog output), 9300 servo plc, System blocks – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 33: Stop, 2 outputs_analog1 (analog output)
9300 Servo PLC
System blocks
2.5
ANALOG1_IO (node number 11)
2−27
L
9300 Servo PLC EN 5.1
Terminal assignment
·
Set via C0034 whether the input is to be used for a master voltage or a master current.
·
Set jumper bar X3 according to setting in C0034:
Stop!
Do not plug the jumper on 3−4! The PLC cannot be initialised in this case.
Terminal
Use
Jumper X3
Measuring range
X6/1, 2
Differential input for
master voltage
6
4
2
5
3
1
C0034 = 0
Level:
Resolution:
Scaling:
−10 V ... +10 V
5 mV (11 bits + sign)
±10 V º ±16384 º ±100 %
Differential input for
master current
6
4
2
5
3
1
C0034 = 1
Level:
Resolution:
Scaling:
+4 mA ... +20 mA
20
mA (10 bits without sign)
+4 mA
º 0 º 0 %
+20 mA
º +16384 º +100 %
C0034 = 2
Level:
Resolution:
Scaling:
−20 mA ... +20 mA
20
mA (10 bits + sign)
±20 mA º ±16384 º ±100 %
2.5.2
Outputs_ANALOG1 (analog output)
The output can be used as a monitor output. Internal analog signals can be output as voltage signals
via terminal X6/62 and used, for instance, as display values or setpoints for slave drives.
Outputs_ANALOG1
AOUT1_nOut_a
C0434
X6
62
Fig. 2−10
Outputs_ANALOG1
System variables
Variable
Data type
Signal type
Address
Display
code
Display
format
Note
AOUT1_nOut_a
Integer
Analog
%QW11.0
C0434
dec [%]
Analog output 1
Terminal assignment
Terminal
Use
Measuring range
X6/62
Analog output 1 (monitor 1)
Level:
Resolution:
Scaling:
−10 V ... +10 V (max. 2 mA)
20 mV (9 bits + sign)
±10 V º ±16384 º ±100 %
X6/7
Internal ground, GND
−