beautypg.com

9300 servo plc, System blocks, 2 touch probe (tp) – Lenze DDS Target 9300 Servo PLC V8.x User Manual

Page 47: 8 dfin_io_digitalfrequency (node number 21), Touch probe configuration

background image

9300 Servo PLC

System blocks

2.8

DFIN_IO_DigitalFrequency (node number 21)

2−41

L

9300 Servo PLC EN 5.1

2.8.1.2

Touch probe (TP)

Process: The current phase value (digital frequency input value) is saved by a quick interrupt in the
operating system when a signal change occurs at the TP activating input (e.g. X5/E5).

DF_IN

DFIN_bEncFaultCable_b

C0426

C0427

X9

C0425

4V

(X9/8)

1

0

E5

TP/MP

-Ctrl

C0428

C0429

MONIT_SD3

DFIN_nIn_v

DFIN_bTPReceived_b

DFIN_dnIncLastScan_p

NNumerator

Ndenominator

nIn_a

nOut_a

L_CONV

X5

Fig. 2−18

Function chart of a TP

 Time−equidistant start of an interval task
j Angle signal

Touch probe configuration

Code

LCD

Possible settings

Info

Lenze

Selection

C0428 DFIN TP sel.

0

Touch probe selection

0

Touch probe via zero pulse

1

Touch probe through digital input X5/E5

C0429 TP delay

0

Touch probe delay

·

Compensation of delay times of
the TP signal source at X5/E5

−32767

{1 inc}

32767

C0431 DFIN TP EDGE

0

Touch probe activation

·

For touch probe via digital input
X5/E5 (C0428 = 1)

0

Activation with positive signal

1

Activation with negative signal