The below table gives you an overview of the memories available:

Memory

Size

Info

ROM

Program memory

384 kbytes

Re−written whenever the program is downloaded

Application data memory
(FLASH)

15 segments

à 64 kbytes

For data and motion profiles (cam data).

·

Data are preserved even after repeated program downloads or firmware
updates.

·

Use the command
Online

WReset (original) in the DDS online mode to delete data.

RAM

PLC data memory

10 kbytes

Can be symbolically used for FB instances and PLC variables.

Application data memory

2 blocks

à 64 kbytes

Data gets lost after mains disconnection.

E2PROM−buffered memory

Retain memory

160 bytes

See subsection 3.3.1

Persistent memory

32 bytes

See subsection 3.3.2

Tip!

The LenzeMemDrv.lib function library includes functions for read/write access to the additional
backup memory (application data memory, FLASH) of the PLC.

·