9300 servo plc, Appendix, 6 code table – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 146
3.6
Code table
9300 Servo PLC
Appendix
3−140
L
9300 Servo PLC EN 5.1
Code
Information
Possible settings
LCD
Code
Information
Selection
Lenze
LCD
C0545 PH offset
0
Digital frequency output DFOUT_IO_DigitalFrequency:
Phase offset of the zero pulse for incremental encoder
simulation (1 rev. = 65535 inc.)
0
{1 inc}
65535
C0547 DFOUT_nOut_v
g
Digital frequency output DFOUT_IO_DigitalFrequency:
DFOUT_nOut_v as analog value (if C0540 = 0)
−199.99
{0.01 %}
199.99
C0549 DFOUT_nOut_v
g
Digital frequency output DFOUT_IO_DigitalFrequency:
DFOUT_nOut_v as speed value (if C0540 = 1)
−32767
{1 rpm}
32767
C0559 SD8 filter t
1.00
Filter time constant (SD8)
1
{1 ms}
200 Example:
When the setting is "10 ms", an SD8 TRIP is initiated after
10 ms.
C0575 max fld weak
4.00
Factor for limiting the max. possible field weakening
·
Setting "4.00" means, for example, max. 400 % field
weakening possible.
1.00
{0.01}
8.00
C0576 nErr Window
100
Tolerance margin for speed monitoring
·
Referred to n
max
.
·
100 % = lowest monitoring sensitivity.
0
{1 %}
100
C0577 Vp fld weak
3.00
Field weakening controller gain V
p
0.00
{0.01 ms}
15.99
C0578 Tn fld weak
10.0
Field weakening controller reset time Tn
2.0
{0.5 ms}
8192.0
8000 ms = switched off
C0579 MONIT nErr
3
Speed monitoring configuration
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP
C0580 MONIT SD8
3
Monitoring configuration: Sin/cos encoder
0
TRIP
3
Off
·
Setting of the filter time constant (SD8) via C0559
C0581 MONIT Eer
0
Monitoring configuration: External error
0
TRIP
1
Message
2
Warning
3
Off
C0582 MONIT OH4
2
Monitoring configuration: Heatsink temperature
(Heatsink temperature > limit temperature C0122)
2
Warning
3
Off
C0583 MONIT OH3
à
Monitoring configuration: Motor temperature
(Motor temperature > fixed limit temperature)
à
Dependent on C0086
0
TRIP
3
Off
C0584 MONIT OH7
à
Monitoring configuration: Motor temperature
(Motor temperature > variable limit temperature C0121)
à
Dependent on C0086
·
Temperature monitoring via resolver input
2
Warning
3
Off