9300 servo plc, System blocks, System variables – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 56
2.11
FCODE_FreeCode (node number 141)
9300 Servo PLC
System blocks
2−50
L
9300 Servo PLC EN 5.1
System variables
Variable
Data type
Signal type
Address
Display
code
Display
format
Note
FCODE_nC17_a
Integer
Analog
%IW141.0
−
−
Default = 50 rpm
FCODE_nC26_1_a
%IW141.2
Default = 0.00 %
FCODE_nC26_2_a
%IW141.3
Default = 0.00 %
FCODE_nC27_1_a
%IW141.4
Default = 100.00 %
FCODE_nC27_2_a
%IW141.5
Default = 100.00 %
FCODE_nC32_a
%IW141.6
Default = 1
FCODE_nC37_a
%IW141.7
Default = 0 rpm
FCODE_nC108_1_a
%IW141.8
Default = 100.00 %
FCODE_nC108_2_a
%IW141.9
Default = 100.00 %
FCODE_nC109_1_a
%IW141.10
Default = 0.00 %
FCODE_nC109_2_a
%IW141.11
Default = 0.00 %
FCODE_nC141_a
%IW141.12
Default = 0.00 %
FCODE_bC250_b
Bool
Binary
%IX141.13.0
−
−
Default = 0
FCODE_bC471Bit0_b
...
FCODE_bC471Bit15_b
Bool
Binary
%IX141.14.0
...
%IX141.14.15
−
−
Default = 0
FCODE_bC471Bit16_b
...
FCODE_bC471Bit31_b
%IX141.15.0
...
%IX141.15.15
FCODE_nC472_1_a
...
FCODE_nC472_20_a
Integer
Analog
%IW141.16
...
%IW141.35
−
−
Default = 0.00 %
C0472/3 = 100.00 %
FCODE_nC473_1_a
...
FCODE_nC473_10_a
Integer
Analog
%IW141.36
...
%IW141.45
−
−
Default = 0
C0473/1, 2 = 1
FCODE_dnC474_1_p
...
FCODE_dnC474_5_p
Double integer
Position
%ID141.23
...
%ID141.27
−
−
Default = 0
FCODE_nC475_1_v
Integer
Velocity
%IW141.56
−
−
Default = 0
FCODE_nC475_2_v
%IW141.57
FCODE_bC135Bit0_b
...
FCODE_bC135Bit15_b
Bool
Binary
%IX141.58.0
...
%IX141.58.15
−
−
Default = 0