9300 servo plc, Appendix, 6 code table – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 153
9300 Servo PLC
Appendix
3.6
Code table
3−147
L
9300 Servo PLC EN 5.1
Code
Information
Possible settings
LCD
Code
Information
Selection
Lenze
LCD
C2120 AIF: Control
0
AIF−CAN: Control word
0
[1]
255
Decimal value is bit−coded:
Note: The state of the MSB (bit 7) of the control word
automatically changes with each access to the code. Please
take this into account when interpreting the data!
0
No command
1
Read XCAN code + new initialization
2
Read XCAN codes
10
Read XCAN C2356/1 ... 4
11
Read XCAN C2357
12
Read XCAN C2375
13
Read XCAN C2376 ... C2378
14
Read XCAN C2382
255
Not assigned
C2121 AIF: state
g
AIF−CAN: Status
·
Detailed information can be found in the documentation
for the corresponding fieldbus module.
0
{dec}
255
Decimal value is bit−coded:
Bit 0
XCAN1_IN monitoring time
Bit 1
XCAN2_IN monitoring time
Bit 2
XCAN3_IN monitoring time
Bit 3
XCAN bus off
Bit 4
XCAN operational
Bit 5
XCAN pre−operational
Bit 6
XCAN warning
Bit 7
Internally assigned
C2130 FileNameAddDa
g
Symbolic name of data
Information about the additional data that was transferred
to the PLC together with the PLC program.
·
More detailed information can be found in chapter
3.3.3, "Downloading data".
^ 3−104
C2131 Type AddData
g
Data type
C2132 VersionAddData
g
Data version
C2133 TimeStamp
g
Time stamp of data
C2350 XCAN address
1
AIF−CAN: Node address
1
{1}
63
C2351 XCAN baudrate
0
AIF−CAN: Baud rate
0
500 kbit/s
1
250 kbps
2
125 kbps
3
50 kbps
4
1000 kbps
5
20 kbps
6
10 kbps
C2352 CAN mst
0
AIF−CAN: Set−up "quasi" master
·
Controller sends system bus boot−up and is thus the
"quasi" master.
0
Boot−up not active
1
Boot−up active
C2353 CAN addr sel1
AIF−CAN: Source for PDO identifiers
0
Identifier assignment via C2350 + basic identifier
1
Identifier assignment via C2354/x
1
0
XCAN1_IN/OUT
2
0
XCAN2_IN/OUT
3
0
XCAN3_IN/OUT