System error messages
9300 Servo PLC
Appendix
3−108
L
9300 Servo PLC EN 5.1
System error message
Possible settings/response
· Lenze setting ü setting possible
Available in
No.
Display
Source
Meaning
Code
TRIP
Message
Warning
FAIL−QS
P
Off
Drive
PLC
Servo
PLC
ECSxA
x089 PL
MCTRL
Error during rotor position adjustment
·
ь
ь
x091 EEr
FWM
External monitoring activated via DCTRL
C0581
·
ь
ь
ь
ь
ь
ь
x105 H05
internal
Internal error (memory)
·
ь
ь
ь
x107 H07
internal
Internal error (power stage)
·
ь
ь
x108 H08
internal
Extension board not connected correctly or not
supported by program
·
ь
ь
x110 H10
FWM
Temperature sensor error: heatsink
temperature
C0588
·
ь
ь
ь
x111 H11
FWM
Temperature sensor error: temperature inside
the controller
·
ь
ь
ь
FIF−CAN / CAN−AUX communication error:
x122 CE11
FIF−CAN1 FIF−CAN1_IN (monitoring time can be set under
C2457/1)
C0591
ь
ь
·
ь
CANaux1 CANaux1_IN (monitoring time can be set under
C2457/1)
C2481
ь
ь
·
ь
x123 CE12
FIF−CAN2 FIF−CAN2_IN (monitoring time can be set under
C2457/2)
C0592
ь
ь
·
ь
CANaux2 CANaux2_IN (monitoring time can be set under
C2457/2)
C2482
ь
ь
·
ь
x124 CE13
FIF−CAN3 FIF−CAN3_IN (monitoring time can be set under
C2457/3)
C0593
ь
ь
·
ь
CANaux3 CANaux3_IN (monitoring time can be set under
C2457/3)
C2483
ь
ь
·
ь
x125 CE14
FIF−CAN
FIF−CAN BUS−OFF status
(too many faulty telegrams received)
C0595
ь
ь
·
ь
FIF−CAN
FIF−CAN BUS−OFF status
(too many faulty telegrams received)
C2484
ь
ь
·
ь
x126 CE15
FIF−CAN
Communication error of the gateway function
(C0370, C0371) via FIF−CAN
C2485
ь
ь
·
ь
x190 nErr
MCTRL
Speed out of tolerance margin (C0576)
C0579
ь
ь
ь
ь
·
ь
ь
x200 NMAX
MCTRL
Maximum speed exceeded (C0596)
·
ь
ь
Time−out (see task configuration):
x201 overrun Task1
internal
Task with ID 2
2)
·
ь
ь
ь
ь
ь
x202 overrun Task2
Task with ID 3
x203 overrun Task3
Task with ID 4
x204 overrun Task4
Task with ID 5
x205 overrun Task5
Task with ID 6
x206 overrun Task6
Task with ID 7
x207 overrun Task7
Task with ID 8
x208 overrun Task8
Task with ID 9
x219 overrun Cycl.−T
internal
Time−out in cyclic task (PLC_PRG, ID 1)
2)
·
ь
ь
ь
ь
ь
x: 0 = TRIP, 1 = Message, 2 = Warning, 3 = FAIL−QSP
2)
In DDS adjustable under Project
W Exception response