beautypg.com

Digital_io (node number 1), Inputs_digital (digital inputs), 10 digital_io (node number 1) – Lenze DDS Target 9300 Servo PLC V8.x User Manual

Page 53: 9300 servo plc, System blocks, 1 inputs_digital (digital inputs), System variables, Electrical data of the input terminals

background image

9300 Servo PLC

System blocks

2.10

DIGITAL_IO (node number 1)

2−47

L

9300 Servo PLC EN 5.1

2.10

DIGITAL_IO (node number 1)

2.10.1

Inputs_DIGITAL (digital inputs)

This SB reads in the signals at the terminals X5/E1 ... E5 and conditions them.

C0443

X5

Inputs_DIGITAL

1

0

C0114/1...5

E3

28

E5

E1

E4

E2

1

DCTRL-X5/28

DIGIN_bIn1_b

DIGIN_bIn2_b

DIGIN_bIn5_b

DIGIN_bIn4_b

DIGIN_bIn3_b

DIGIN_bCInh_b

Fig. 2−21

Inputs_DIGITAL

System variables

Variable

Data type

Signal type

Address

Display

code

Display

format

Note

DIGIN_bCInh_b

Bool

Binary

%IX1.0.0

Controller inhibit (CINH) acts
directly on the DCTRL control.

DIGIN_bIn1_b

%IX1.0.1

C0443

bin

DIGIN_bIn2_b

%IX1.0.2

DIGIN_bIn3_b

%IX1.0.3

DIGIN_bIn4_b

%IX1.0.4

DIGIN_bIn5_b

%IX1.0.5

Electrical data of the input terminals

Terminal

Use

Measuring range

X5/28

Controller enable (RFR)

LOW level:
HIGH level:
Input current:

0 ... +4 V
+13 ... +30 V
8 mA per input (at 24 V)

X5/E1

Interrupt−capable

1

Touch−probe−capable

2

Freely

assignable

X5/E2
X5/E3
X5/E4

TP signal, actual motor speed
X7 (resolver), X8 (encoder)

1

Response time of the interrupt task: < 250

ms

2

Use of X5/E1 ... E3 as a touch probe input:

See "Function library LenzeTpDrv.lib" manual

X5/E5

TP signal
X9 (digital frequency input)

X5/39

Ground (GND) of digital inputs and outputs

·

The terminal polarity of the inputs X5/E1 ... E5 can be configured under C0114:

Code

LCD

Possible settings

Info

Lenze

Selection

C0114 DIGIN pol

Terminal polarity

0

HIGH active

1

LOW active

1

1

X5/E1

2

1

X5/E2

3

0

X5/E3

4

0

X5/E4

5

0

X5/E5