9300 servo plc, Appendix, 5 system error messages – Lenze DDS Target 9300 Servo PLC V8.x User Manual
Page 115

9300 Servo PLC
Appendix
3.5
System error messages
3−109
L
9300 Servo PLC EN 5.1
System error message
Possible settings/response
· Lenze setting ü setting possible
Available in
No.
Display
Source
Meaning
Code
TRIP
Message
Warning
FAIL−QS
P
Off
Drive
PLC
Servo
PLC
ECSxA
Floating−point error (REAL) in:
x209 FLOAT SYS−T
internal
System task
2)
·
ь
ь
ь
ь
ь
x210 FLOAT CYCL.−T
Cyclic task (PLC_PRG, ID 1)
x211 float T Id2
Task with ID 2
x212 float T Id3
Task with ID 3
x213 float T Id4
Task with ID 4
x214 float T Id5
Task with ID 5
x215 float T Id6
Task with ID 6
x216 float T Id7
Task with ID 7
x217 float T Id8
Task with ID 8
x218 float T Id9
Task with ID 9
x220 NoT−FktCredit
internal
Not enough technology units available in the
PLC
·
ь
ь
ь
x230 No Program
internal
No PLC program loaded in PLC
·
ь
ь
ь
x231 Unallowed Lib
internal
A library function has been called in the PLC
program which is not supported
·
ь
ь
ь
x232 NoCamData
internal
Motion profiles (cam data) are not available
·
ь
ь
ь
Free CAN objects:
x240 ovrTransQueue
Free CAN
obj.
Overflow of send order memory
C0608
·
ь
ь
ь
3)
ь
ь
ь
ь
x241 ovr Receive
Too many receive telegrams
C0609
·
ь
ь
ь
Application memory (FLASH):
x250 2.Flash Err
internal
Access not possible
1)
(FLASH memory defective or not available)
·
ü
x251 AddData CsErr
internal
Check sum error occurred when loading data
into the FLASH memory
x252 AddData DlErr
internal
Error occurred when downloading data into the
FLASH memory (e.g. time−out)
x260 Err NodeGuard
Node
guarding
"Life guarding event": The PLC as a CAN slave
has not received any "node guarding" telegram
within the node lifetime of the CAN master.
C0384
·
ь
ь
ь
3)
ь
ь
ь
ь
x: 0 = TRIP, 1 = Message, 2 = Warning, 3 = FAIL−QSP
1)
After error correction: completely deenergise the device!
2)
In DDS adjustable under Project
W Exception response
3)
Only with 9300 Servo PLC!