beautypg.com

Festo Контроллер позиционирования CPX-CMPX User Manual

Page 99

background image

3. Installation

3−19

Festo P.BE−CPX−SYS−EN en 0902e

Plugs
(t

i

Interlinking block with

(top view
of device)

System supply
Type CPX−(M−)GE−EV−S...

Additional power supply
Type CPX−(M−)GE−EV−Z...

Valve supply
Type CPX−GE−EV−V...

7/8"−4POL

1)

D

C

B

A

A: 24 V

el/sen

B: 24 V

val

/ 24 V

out

C: FE
D: 0 V

el/sen

/

0 V

val

/ 0 V

out

A: not connected
B: 24 V

out

C: FE
D: 0 V

out

A: not connected
B: 24 V

val

C: FE
D: 0 V

val

7/8"−5POL

1

2

3

4

5

1: 0 V

val

/ 0 V

out

2: 0 V

el/sen

3: FE
4: 24 V

el/sen

5: 24 V

val

/ 24 V

out

1: 0 V

out

2: not connected
3: FE
4: not connected
5: 24 V

out

ć

M18

1

2
3

4

1: 24 V

el/sen

2: 24 V

val

/ 24 V

out

3: 0 V

el/sen

/

0 V

val

/ 0 V

out

4: FE

1: not connected
2: 24 V

out

3: 0 V

out

4: FE

1: not connected
2: 24 V

val

3: 0 V

val

4: FE

Push−pull

2)

1: 24 V

el/sen

2: 0 V

el/sen

3: 24 V

val

/ 24 V

out

4: 0 V

val

/ 0 V

out

5: FE

1: not connected
2: not connected
3: 24 V

out

4: 0 V

out

5: FE

ć

V

el/sen

:

Operating voltage for electronics/sensors

V

out

:

Load voltage for outputs

V

val

:

Load voltage for valves

FE:

Functional earth

1)

Note the specifications on the plug.

2) Interlinking blocks with forwarding function and interlinking blocks with system supply are

identically constructed.

Tab. 3/4: Pin assignment for interlinking blocks with system supply, additional supply or

valve supply