Festo Контроллер позиционирования CPX-CMPX User Manual
Page 112
4. Commissioning
4−8
Festo P.BE−CPX−SYS−EN en 0902e
Channel−specific parameters
Brief description
Signal extension
Serves for recognising short signals
Monitoring of wire break
Serves for recognising connection faults
Fault mode
Defines the status that the relevant channel is to assume in
the event of fieldbus communication faults
Fault state
the event of fieldbus communication faults.
Idle mode
Defines the status which digital output signals (outputs and
valves) are to assume when the Idle function is accessed. This
Idle state
valves) are to assume when the Idle function is accessed. This
function is only relevant with certain fieldbus protocols (see
manual for specific CPX bus node).
Force mode
Actual signals are replaced in the processing image by the force
settings
Force state
settings.
Tab. 4/4: Module parameters ć part 2
Detailed information on the parameters, which are supported
by the module you are using used, can be found in the manĆ
ual for the relevant module. Basic principles of using the
parameters can be found in Appendix C.
Diagnostic memory parameĆ
ters
Brief description
Entries, remanent
Determines whether the contents of the diagnostic memory are
to be retained after new Power on or whether they are to be deĆ
leted.
Diagnostic memory filters
Ĉ Run/stop filter 1 + 2
Ĉ Fault end filter
Ĉ Fault number filter
Ĉ Module/channel filter
With the diagnostic memory filters you can suppress the regisĆ
tering of certain error messages and control both the starting
and stopping of the fault registering.
Tab. 4/5: Diagnostic memory parameters