4. Commissioning

4−8

Festo P.BE−CPX−SYS−EN en 0902e

Channel−specific parameters

Brief description

Signal extension

Serves for recognising short signals

Monitoring of wire break

Serves for recognising connection faults

Fault mode

Defines the status that the relevant channel is to assume in
the event of fieldbus communication faults

Fault state

the event of fieldbus communication faults.

Idle mode

Defines the status which digital output signals (outputs and
valves) are to assume when the Idle function is accessed. This

Idle state

valves) are to assume when the Idle function is accessed. This
function is only relevant with certain fieldbus protocols (see
manual for specific CPX bus node).

Force mode

Actual signals are replaced in the processing image by the force
settings

Force state

settings.

Tab. 4/4: Module parameters ć part 2

Detailed information on the parameters, which are supported
by the module you are using used, can be found in the manĆ
ual for the relevant module. Basic principles of using the
parameters can be found in Appendix C.

Diagnostic memory parameĆ
ters

Brief description

Entries, remanent

Determines whether the contents of the diagnostic memory are
to be retained after new Power on or whether they are to be deĆ
leted.

Diagnostic memory filters

Ĉ Run/stop filter 1 + 2
Ĉ Fault end filter
Ĉ Fault number filter
Ĉ Module/channel filter

With the diagnostic memory filters you can suppress the regisĆ
tering of certain error messages and control both the starting
and stopping of the fault registering.

Tab. 4/5: Diagnostic memory parameters