A. Technical appendix

A−6

Festo P.BE−CPX−SYS−EN en 0902e

Load voltage of the valves

Power supply
Ĉ Nominal value

Ĉ Tolerance

*)

DC 24 V (reverse polarity protected)

Ĉ Without pneumatics:

18 ... 30 V

Ĉ With CPX−CP interface:

20.4 ... 26.4 V

Ĉ With pneumatics of type MPA:

18 ... 30 V

Ĉ With pneumatics of type VTSA:

21.6 ... 26.4 V

Ĉ With pneumatics of type Midi/Maxi:

21.6 ... 26.4 V

Ĉ With pneumatics of type CPA:

20.4 ... 26.4 V

Current consumption

Current consumption of the pneumatic interface:
see manual for the CPX I/O modules",
type P. BE−CPX−EA−...
Sum of all switched−on valve solenoid coils; see
specific Pneumatics manual

Residual ripple

4 Vpp (within tolerance)

*) The module with the lowest tolerance is always decisive for the permitted voltage tolerances (see

manual for relevant module or for relevant pneumatics).

Special technical specifications on the pneumatics used, on
CPX modules, connection blocks and the CPX bus node can
be found in the relevant manuals.