beautypg.com

Festo Контроллер позиционирования CPX-CMPX User Manual

Page 79

background image

2. Assembly

2−35

Festo P.BE−CPX−SYS−EN en 0902e

Variant

Mounting points

1

2

2

3

4

CPX terminal in plastic version with VTSA
pneumatics
Required mounting with:
Ĉ Left end plate

1 : two M4 or M6 screws

Ĉ For each additional mounting bracket

(not shown, needed if 4 or more inter−
linking blocks are used, see Tab. 2/4),
type CPX−BG−RW−...: one M4 screw

Ĉ Pneumatic interface

2: two M6 screws

with internal hex

Ĉ Optional: Mounting bracket

3 (second

variant not shown) for VTSA pneumatics
on the pneumatic supply plate: one M5
screw or one M5 and one M6 screw

Ĉ Right end plate

4: two M6 screws

1

2

3

CPX terminal in plastic version with Midi/
Maxi pneumatics
Required mounting with:
Ĉ Left end plate

1: two M4 or M6 screws

Ĉ For each additional mounting bracket

(not shown, needed if 4 or more inter−
linking blocks are used, see Tab. 2/4),
type CPX−BG−RW−...:one M4 screw

Ĉ Pneumatic interface

2: two M6 screws

Ĉ Right end plate

3: two M6 screws

Т

Т

Т

ТТ

ТТ

ТТ

1

2

2

3

CPX terminal in plastic version with CPA
pneumatics
Required mounting with:
Ĉ Left end plate

1: two M4 or M6 screws

each

Ĉ For each additional mounting bracket

(not shown, needed if 4 or more inter−
linking blocks are used, see Tab. 2/4),
type CPX−BG−RW−...:
one M4 screw

Ĉ Pneumatic interface:

two (optionally three) M4 screws

2

Ĉ Right end plate

3: two M4 screws

Tab. 2/6: Mounting points required for wall mounting (part 2)