5. Diagnostics and error handling
5−27
Festo P.BE−CPX−SYS−EN en 0902e
Error numbers of error class 2
No.
Eliminating faults
Operating status
Handheld display
110
...114
Reserved
115
[Subsystem module/
channel failure]
Module/channel in a subordiĆ
nate system has failed
Check subordinate module
(function/installation),
replace if necessary
See manual for the relevant
module
Tab. 5/8: Possible faults (fault class 2)
Error numbers of error class 3
No.
Handheld texts
Operating status
Eliminating faults
128
[Switch unit defective]
Hardware defective in the
switch unit
Check module, if necessary
replace
129
[CBUS asic not ready]
Hardware defective
Replace module
130
[CPU Hardware Trap]
System error has occurred
Replace module if Power Off/
On does not remedy problem
131
[CBUS C−manager not
ready]
Fault in internal communicaĆ
tion
Check CPX terminal and, if neĆ
cessary, replace
132
[Watchdog overflow]
System error has occurred
Replace module if Power Off/
On does not remedy problem
133
[Remanent memory defecĆ
tive]
Hardware defective
Replace module
134
[Flash system memory
defective]
Hardware defective
Replace module
135
[Number of mod. paĆ
rams.more than 64]
Fault in internal configuration
Check CPX terminal and,
if necessary, replace
136
[Slave not ready]
System error has occurred
Replace module if Power Off/
On does not remedy problem
137
[CBUS diagnostic telegram]
Fault in internal communicaĆ
tion
Check CPX terminal and,
if necessary, replace