Festo Контроллер позиционирования CPX-CMPX User Manual
Page 182
B. Parameters and data of the CPX terminal
B−28
Festo P.BE−CPX−SYS−EN en 0902e
Diagnostic memory parameter: Channel number (CN)
Function no.
3486
Description
Channel number for the diagnostic memory filter
Bit
0...7
(1 byte)
Values
Channel number (CN)
0...63
Channel number (0 = presetting)
[Channel number CN]
Note
Is only effective if an appropriate diagnostic memory filter is active.
Tab. B/31: Channel number (CN)
Diagnostic memory parameter: Fault number (FN)
Function no.
3487
Description
Fault number for the diagnostic memory filter
Bit
0...7
(1 byte)
Values
Fault number (FN)
0...255
Fault number (0 = presetting)
[Fault number FN]
Note
Is only effective if an appropriate diagnostic memory filter is active.
Tab. B/32: Fault number (FN)