C. General information on parametrisation

C−24

Festo P.BE−CPX−SYS−EN en 0902e

Monitoring

Reaction to activation

Module parameters
Monitoring

A fault on the module will be:
Ĉ Forwarded to the CPX bus node
Ĉ Displayed by the module common error LED

System parameters
Monitoring

A fault registered by the module will be:
Ĉ Sent to the higher−order fieldbus master
Ĉ Displayed by the red SF−LED on the CFX bus node
Ĉ Entered in the module diagnostic data and, if applicable, in the

status bits

Ĉ Entered, if applicable, in the diagnostic memory

Tab. C/8: Monitoring

The behaviour of the channel fault LED is normally controlled
by hardware functions and does not therefore depend on the
setting of the monitoring functions.

The following monitoring functions can be activated or deactiĆ
vated globally:

System parameter monitoring

Description

Undervoltage of valves

Monitors the load voltage supply for the valves

Undervoltage of outputs

Monitors the load voltage supply for the outputs

Short circuit/overload of outputs

Monitors whether outputs are overloaded or short circuiĆ
ted

Short circuit/overload, sensor supply

Monitors whether sensor supply is overloaded or short
circuited

Tab. C/9: System parameter monitoring