Festo Контроллер позиционирования CPX-CMPX User Manual
Page 57
2. Assembly
2−13
Festo P.BE−CPX−SYS−EN en 0902e
Assembly
Fit the tie rod and the electric modules or interlinking blocks
as follows (see Fig. 2/6):
Note
·
Place subsequently ordered modules where possible
after the last module before the pneumatic interface or
in front of the right−hand end plate.
·
Do not fit more than 10 electric modules and one pneuĆ
matic interface.
·
Fit modules of the same type where possible in series
(e.g. first all input modules then all output modules).
This can be an advantage for the address assignment of
the CPX terminal, depending on the fieldbus used.
1. Fasten the tie rod in the pneumatic interface or the right−
hand end plate, by placing the fastening plate over the
locking plate and pushing these together into the groove
intended for this purpose. The locking plate must lie on
the side facing the pneumatics. The hooks on the locking
plate must grip into the grooves in the fastening plate.
1
Locking plate
2
Fastening plate
3
Groove for tie rod
fastening
1
2
3
Fig. 2/6:
Fastening plate and locking plate in the pneumatic interface