B. Parameters and data of the CPX terminal
B−12
Festo P.BE−CPX−SYS−EN en 0902e
System parameter: System Idle mode
Function no.
4402
Description
Establishes which signal status outputs/valves are to assume when the CPX
terminal switches into the Idle state.
In the following case, the channel−orientated Idle mode settings (module paraĆ
meters Idle mode and Idle state) are reset automatically for safety reasons in
order to avoid undesired signal states.
Ĉ When changing from Idle fault mode" to Reset all outputs" or to Hold last
state".
Bit
Bits 4, 5
Values
Bit 5 4
0 0
System Idle mode
Description
Reset all outputs (presetting)
[Idle mode]
[Reset outputs]
0 1
Hold last state (retain signal status)
[Hold last state]
1 0
Assume Idle mode
Assume idle mode]
Note
Only relevant for certain fieldbus protocols Explanations on this can be found in
the manual for the relevant CPX bus node.
Tab. B/7: Idle mode