beautypg.com

Festo Контроллер позиционирования CPX-CMPX User Manual

Page 66

background image

2. Assembly

2−22

Festo P.BE−CPX−SYS−EN en 0902e

2.4.2

Fitting CPX terminals with pneumatics onto an H−rail

For fitting the CPX terminal onto an H−rail you will require
mounting kit type CPX−CPA−BG−NRH. This kit contains
3 clamping components and 3 M4x12 screws.

Caution
H−rails with mounted valve terminals can break if they are
subjected to vibration exceeding severity level 1:

Ĉ 0.15 mm path at 15 ... 85 Hz

Ĉ 2 g acceleration at 58 ... 150 Hz

This can damage the valve terminal, your machine or your
system.

·

In this case use wall mounting.

·

Note the permitted values for vibration and shock in
appendix A.1 Technical data".

Caution
Ĉ H−rail mounting without an H−rail clamping unit is not

permitted.

·

If the terminal is fitted in a sloping position or if it is subĆ
jected to vibration, secure the H−rail clamping unit addiĆ
tionally
ć against sliding down with the retaining screws

intended for this purpose (see

3 in Fig. 2/11)