Festo Контроллер позиционирования CPX-CMPX User Manual
Page 154
A. Technical appendix
A−10
Festo P.BE−CPX−SYS−EN en 0902e
Formula for maximum cable length:
L
v
NJ
ǒ
U
Bmin
* U
OUT
ńVALmin
Ǔ
@ A @ Ë
CU
Nj
{2
@ l
2
) l
1
}
Meaning
·
Without pneumatics: V
OUT/VALmin
w
18 V
With Midi/Maxi pneumatics: V
OUT/VALmin
w
21.6 V
With CPA pneumatics: V
OUT/VALmin
w
20.4 V
·
V
Bmin
= minimum operating voltage supply (on the power
supply unit)
·
Current I
1
= current for electronics and sensors
·
Current I
2
= current for valves and outputs
·
A = cross−sectional area (uniform e.g. 1.5 mm
2
)
·
κ
= conductance value of the cables
(uniform e.g.
κ
CU
= 56
m
mm
2
@
)
ġ
Example:
I1
= 1 A;
I2
= 5 A;
V
Bmin
= 24 V;
CPA pneumatics: V
OUT/VALmin
= 20.4 V;
κ
CU
= 56
m
mm
2
@ ġ
Result:
L
≤ 27.49 m for A = 1.5 mm
2
L
≤ 45.81 m for A = 2.5 mm
2