C. General information on parametrisation

C−21

Festo P.BE−CPX−SYS−EN en 0902e

Fault end filter

Start: Error

Run/stop
Filter 2

Error number filter

Module/channel filter

0 = Always register

1 = Register up to the defined error number

2 = Register up to the defined error number + module number

3 = Register up to the defined error number + module number +

3 =

channel number

4 = Register as from the defined error number

5 = Register as from the defined error number + module number

6 = Register as from the defined error number + module number +

6 =

channel number

Run/stop filter 1

The first 40 faults or the last 40 faults

Register end of fault or not

Register defined error number or not

Register only error number of a module/channel

Diagnostic

memory

MN = module number, CN = channel number, FN = error number

Fig. C/10: The method of operation of the diagnostic memory filters