4 wall mounting, Wall mounting – Festo Контроллер позиционирования CPX-CMPX User Manual
Page 73
2. Assembly
2−29
Festo P.BE−CPX−SYS−EN en 0902e
2.4.4
Wall mounting
Caution
When fitted onto a wall, the CPX terminal can bend and be
damaged in the following cases:
Ĉ When fitted to an uneven, flexible surface
Ĉ When CPX terminals with Midi/Maxi pneumatics are
fitted without spacer discs (see Fig. 2/15)
Ĉ When fitted to a wall without additional fastening (see
Tab. 2/4)
Fit the CPX terminal only onto a flat fixed surface. Make
sure that the spacer discs are fitted before you mount the
CPX terminal with Midi/Maxi pneumatics.
The end plates and the pneumatic interface contain holes for
fitting the terminal onto a wall.
Spacer discs for Midi/Maxi pneumatics
To compensate for the differences in height between the
pneumatic and electrical sides, you have to fit spacer discs
for a CPX terminal with Midi/Maxi pneumatics. Fit two spacer
discs on each of the following:
ć
On the pneumatic interface for Midi/Maxi
ć
On the end plate
The spacer discs have one self−adhesive side to simplify the
assembly process. Remove the protective foil before mountĆ
ing.
Note Fig. 2/15 and the relevant fitting instructions.