Allied Telesis AT 8000/8POE User Manual
Page 230

Chapter 19: Basic Switch Parameters
230
Section II: Web Browser Interface
Note
For information about the SNMP Agent selection, refer to “Enabling
or Disabling the SNMP Agent” on page 256.
2. To configure the console UI time out parameters, do the following:
a. In the Console UI Time Out field, enter a new value.
The range is 0 to 60 minutes. The default is 5 minutes. A timeout
value of 0 causes the console connection to never times out.
The console idle time out parameter specifies the length of time a
local management session can be inactive before the management
software automatically ends it. The purpose of this parameter is to
prevent unauthorized individuals from configuring the switch
should you leave your management workstation unattended.
This parameter applies to a local management session but not to a
web management session. A web browser management session
remains active so long as your web browser is open.
Note
If you select 0, you must remember to properly log off from a local
management session when you are finished to prevent blocking
future management sessions with the switch.
b. Click Apply.
3. To configure the Telnet UI timeout value, do the following:
a. In the Telnet UI Time Out field, enter a new value.
The Telnet idle time out parameter specifies the length of time that
a remote Telnet management session can be inactive before the
management software automatically ends it.
4. To change the user settings, do the following:
a. Enter the existing name and password in the User Name and
Password fields. The default name and password are both
“manager”. The login name and password are case sensitive.
b. Click the New User Name field and enter a new user name or, if
you do not want to change the login name, enter the current name.
Leaving this field empty deletes the current login name without
assigning a new one. The name can be from 0 to 12 characters.
Spaces are allowed. The login name is case sensitive.