Chapter 8: Verifying the Hardware Operations of the Chassis

200

update the firmware on the control card. For instructions, refer to the
Software Reference for SwitchBlade x3100 Series Switches.

3. To display the status of the power supplies, enter the SHOW PSU

command.

An example of the status information is shown in Figure 149. The
power supplies are operating normally when the states are UP-UP. If
there is a problem with a power supply, refer to “AT-SBxPWRSYS1
and AT-SBxPWRPOE1 AC Power Supplies” on page 204
or “AT-
SBxPWRSYS1 DC Power Supply” on page 205 for
troubleshooting
suggestions.

Figure 149. SHOW PSU Command

4. To display the state of the fan module, enter the SHOW FANMODULE

command.

The module is operating normally when its state is UP-UP-ONLINE, as
shown in Figure 150. If the state of the fan module is something other
than UP-UP-ONLINE, power off the chassis and contact your Allied
Telesis representative for assistance. Do not operate the chassis
without a fully operational fan unit.

Figure 150. SHOW FANMODULE Command

5. To view the states of the controller and line cards in the chassis, use

the SHOW CARD command.

SHOW PSU

--- Power Supply Units ---

Slot Type

State

Temp (C)

A

POE

UP-UP

38

B

POE

UP-UP

38

C

System

UP-UP

38

D

System

UP-UP

38

SHOW FANMODULE

--- Fan Module ---

Fan Module..................... FM2
Module Number.................. AT-SBxFAN06
Serial Number.................. A0428400008
State.......................... UP-UP-Online

Actual

Fan Speed

Fan 1.................. 3897 rpm
Fan 2.................. 3903 rpm

Cold Temperature Shutdown... Off