beautypg.com

Figure 144: connecting the negative lead wire – Allied Telesis SwitchBlade x3106 User Manual

Page 189

background image

SwitchBlade x3106 Installation Guide

189

Figure 144. Connecting the Negative Lead Wire

Allied Telesis recommends tightening the screw to 30 to 40 inch-lbs.

Warning
Check to see if there are any exposed copper strands coming from
the installed wires. When this installation is done correctly there
should be no exposed copper wire strands extending from the
terminal block. Any exposed wiring can conduct harmful levels of
electricity to persons touching the wires.  E12

7. Slide the plastic cover to the left and lightly tighten the two screws with

a #1 Phillips-head screwdriver to secure the cover. See Figure 133 on
page 179
. You might need to lift the locking handle slightly to access
the bottom screw.

Caution

Do not over tighten the screws or you may crack or break the plastic
cover.

8. With a #2 Phillips-head screwdriver, tighten the handle locking screw

to secure the power supply to the chassis. See Figure 134 on page
180
.