Setting up remote copy over ip, Rcip initial remote-copy pair, Rcip initial remote-copy pair worksheet – HP 3PAR Operating System Software User Manual
Page 27: Network and rcip setup—example initial pair, Remote copy rtt
Storage and HP 3PAR 10000 StoreServ Storage systems, individual ports can be configured for
RCFC.
Remote-copy links in asynchronous periodic mode do not have to be dedicated to remote copy,
and can be shared with other traffic, but this is not recommended. The remote-copy links in
synchronous mode require guaranteed bandwidth over dedicated remote-copy links.
RCFC over IP network connections are allowed only for remote copy in asynchronous periodic
mode.
RTT
Maximum round-trip time (RTT) allowed is shown in
Table 1 Remote Copy RTT
RTT
Transport Layer
Volume Group Mode
2.6 ms
RCFC
Synchronous
2.6 ms
RCIP
n/a
FCIP
(Not supported)
2.6 ms
RCFC
Asynchronous periodic
150 ms
RCIP
120 ms
FCIP
Setting Up Remote Copy over IP
RCIP Initial Remote-Copy Pair
illustrates the initial remote-copy pair in an RCIP configuration.
Figure 9 Network and RCIP Setup—Example Initial Pair
RCIP Initial Remote-Copy Pair Worksheet
Figure
is a worksheet for setting up an initial remote-copy pair over RCIP.
Setting Up Remote Copy over IP
27