Quick setup: rcfc transport layer, Quick setup: remote-copy configurations, Quick setup steps for rcfc – HP 3PAR Operating System Software User Manual
Page 254
Quick Setup: RCFC Transport Layer
Table 9 Quick Setup Steps for RCFC
Backup System
Primary System
Reference
Step
controlport offline
controlport offline
“Setting Up Remote-Copy
Interface for RCFC” (page
36)
1.
Take the port offline.
controlport config
rcfc -ct point -f
controlport config
rcfc -ct point -f
“Setting Up Remote-Copy
Interface for RCFC”
(page 36)
2.
On all RCFC ports, set up
the interface.
showport -rcfc
showport -rcfc
“
3.
On all RCFC ports, get
RCFC port positions.
showrctransport -rcfc
controlport rcfc
init -f
“
4.
On each RCFC port,
initialize port.
controlport rcfc init
-f
showrctransport -rcfc
showrctransport
-rcfc
“
5.
On each RCFC port,
verify port is ready
a.
cli checkrclink
startserver
“Checking RCFC Link
Throughput and Latency”
(page 38)
6.
On all nodes, check the
links.
b.
cli checkrclink
startclient
c.
cli checkrclink
stopserver
Quick Setup: Remote-Copy Configurations
“Quick Setup Steps for Unidirectional Pairs: 1-to-1, N-to-1,
and 1-to-N Configurations” (page 255)
1-to-1 Unidirectional
“Quick Setup Steps for the Bidirectional Pair: 1-to-1, N-to-1,
and 1-to-N Configurations” (page 256)
1-to-1 Bidirectional
“Quick Setup Steps for Unidirectional Pairs: 1-to-1, N-to-1,
and 1-to-N Configurations” (page 255)
for each remote-copy
pair (4 max primary:1 backup).
N-to-1
for one remote-copy pair if desired.
“Quick Setup Steps for Unidirectional Pairs: 1-to-1, N-to-1,
and 1-to-N Configurations” (page 255)
for each remote-copy
pair (1 primary:2 max backup).
1-to-N
for one remote-copy pair if desired.
“Quick Setup Steps for Synchronous Long Distance
Configurations” (page 257)
SLD
NOTE:
If you use a script to set up the remote-copy configuration, keep in mind that it takes some
time to establish the TCP/IP connections after the creatercopytarget and admitrcopylink
commands. It can take as long as two minutes for the links to be marked Up and the target marked
ready
.