Corrective actions

Cause/Symptom

This is usually caused when a server is booting and a
power control command is sent to its management

If this is unsuccessful, reset the management processor by
one of the following methods:

processor. Most commonly the system is in a BIOS boot

Upgrade the firmware on the server and management
processor to the most recent version.

and the management processor cannot determine the
power status.

Power cycle the server.

Log into the iLO's web interface and reset it by selecting
Diagnostics under Information or System Status, then
selecting Reset.

Use ssh or telnet to log into the iLO and perform a
reset map1

to reset the iLO.

Select Configure

→Management Processor→Credentials to

modify the credentials for this managed system.

Unable to power off server: Error retrieving BMC for server.
Root cause: Error status "User login name was not found"

This is most commonly caused by incorrect credentials for
the management processor.

For the corrective action, see

Section 25.20 (page 236)

.

Server Control tool fails

The managed system fails to be powered down, powered
up, or rebooted because the target server lost association
with its management processor.

Test the communication with the server’s management
processor with the ping command. If the

MP

does not

Unable to communicate with management processor: Error
retrieving BMC for server. Root cause:PANIC:Error
instantiating BMCManager for BMC of server IP address.

This can occur during an OS installation.

respond, reset it. If the server is a c-Class BladeServer, log
into the

OA

to reset it. For non-blade servers, unplug the

MP.

Powering on the server a second time causes it to boot
normally, and this problem does not reoccur.

Power cycle after HP SIM discovery starts bare metal
discovery

A server that is set to PXE boot all the time might not boot
properly after it is discovered with the Options

→Discovery...

tool.

Instead of booting, the server undergoes a bare metal
discovery process and powers down. This occurs only once
per server.

25.19 Troubleshooting server power control problems 235