Harmonics reactive power qk [var, Harmonics voltage total distortion factor thdvf, Harmonics current total distortion factor thdaf – KYORITSU 6315 Instruction Manual User Manual
Page 148: Used for internal calculation only), Athdaf, Vthdvf

KEW6315
Items measured at Harmonics measurement
KEW6315
- 146 -
Harmonics reactive power Qk [var]
(used for internal calculation only)
Equation
Pc
k
=V
c(10k)r
×A
c(10k)i
-V
c(10k)i
×A
c(10k)r
c: Measurement channel: A
1k,
A
2k,
A
3k,
A
4k
, k: Harmonics of each order
r: Real number after FFT conversion, i: Imaginary number after FFT conversion
Measurement cycle in this equation is 10-cycle. For 12-cycle measurement,
"10k" should be replaced with "12k”.
1P2W-1 to 4
Q
1k
Q
2k,
Q
3k,
Q
4k,
Q
sumk
=Q
1k
+Q
2k
+Q
3k
+Q
4k
1P3W-1 to 2
Q
1k,
Q
2k,
Q
sum1k
=Q
1k
+Q
2k
Q
3k,
Q
4k,
Q
sum2k
=Q
3k
+Q
4k
Q
sumk
=Q
sum1k
+Q
sum2k
3P3W-1 to 2
Q
1k,
Q
2k,
Q
sum1k
=Q
1k
+Q
2k
Q
3k,
Q
4k,
Q
sum2k
=Q
3k
+Q
4k
Q
sumk
=Q
sum1k
+Q
sum2k
3P3W3A
Phase voltage Q
1k
:V
1
= ( V
12
-V
31
)/3
,
Q
2k
:V
2
= ( V
23
-V
12
)/3
,
Q
3k
:V
3
= ( V
31
-V
23
)/3
,
Q
sumk
=Q
1k
+Q
2k
+Q
3k
3P4W
Q
1k,
Q
2k,
Q
3k,
Q
sumk
=Q
1k
+Q
2k
+Q
3k
Harmonics voltage total distortion factor THDVF [%]
Displayed digit
4-digit
Display range
0.0% - 100.0%
Equation
( )
1
100
50
2
2
c
ck
c
V
V
THDVF
k
×
=
∑
=
c: Meas. channel
V: Harmonics voltage
k: Harmonics of each order
1P2W-1 to 4
THDVF
1
1P3W-1 to 2
THDVF
1 ,
THDVF
2
3P3W-1 to 2
Line voltage THDVF
12 ,
THDVF
32
3P3W3A
Line voltage THDVF
12 ,
THDVF
23 ,
THDVF
31
3P4W
THDVF
1 ,
THDVF
2 ,
THDVF
3
Harmonics current total distortion factor THDAF [%]
Displayed digit
4-digit
Display range
0.0% - 100.0%
Equation
( )
1
100
50
2
2
c
ck
c
A
A
THDAF
k
×
=
∑
=
c: Meas. ch THDAF
1 ,
THDAF
2 ,
THDAF
3 ,
THDAF
4
A: Harmonics current
k: Harmonics of each order