Auto-ranging” (current range), Sensor detection, Recovery from power fails – KYORITSU 6315 Instruction Manual User Manual
Page 126: Print screen, Retain settings, Quick start guide, Status indicator

KEW6315
Chap. 7 Other functions
KEW6315
- 124 -
“Auto-ranging” (Current range)
Current ranges of each sensor are automatically switched according to the measured rms currents. This
function does not work while recoding the power quality events. A range shifts to one upper range when
the input exceeds 300%peak of each range and shifts to one lower range when the input drops under
100%peak of each range. However, while “AUTO” is selected, the upper range will be adopted to display
the values.
“Sensor detection”
Press the “Detection” key on the SETUP menu to detect the connected clamp sensors. KEW6315
automatically detects the connected sensors and checks the settings of the sensors.
“Recovery from power fails”
When the power supply to the instrument is inadvertently lost during a record, the interrupted record will
be resumed after the power supply is restored.
“Print screen”
Press the “PRINT SCREEN” Key to save the displayed screen as a BMP (bitmap) file.
* Max file size: approx. 77KB
“Retain settings”
Settings used during the previous test will not be cleared after powering off the instrument. KEW6315
retains and adopts the previous settings. * Default values will be displayed for the first time after purchase.
”Quick start guide”
Press the “START/STOP” Key to run the “Quick start guide”. It is useful to start recording just by adjusting
some simple settings according to the displayed screens.
”Status indicator”
The red indicator LED blinks when the backlight is off, and the green indicator LED stays on during
recording regardless of the backlight states. The green indicator LED blinks during stand-by mode.