beautypg.com

Close loop, 2 peg test – Spectra Precision Survey Pro v4.5 Recon and Nomad Reference Manual User Manual

Page 272

background image

Survey Pro Reference Manual

R-264

Close Loop

The Close Loop screen lists the notes for the current level loop and

allows you to close the current loop. This is the only screen that can

be used to close a loop.

Close Level Loop : closes the current level loop and opens

the Level screen where no additional shots can be taken.

2 Peg Test

Leveling 2 Peg Test

.

The 2 Peg Test screen is used to check that the line of

sight through the level is horizontal when the bubble is

properly centered.

The graphic of this screen shows the current setup and

indicates which shot you will be shooting next with a red

square. The first line of text also indicates which shot
must be taken next.

Check H. Dist : This button only appears after shooting

the initial shots to Point A. This will measure the

horizontal distance to Point B and compare it with the

distance already measured to Point A. Come/go
information is then provided so the rod over Point B can

be moved until it equals the horizontal distance to Point

A. Use of this button is optional and the results are not
used for computing the error.

Take Shot : takes the required sets of shots to the point

indicated on this screen.