Video scan settings – Spectra Precision Survey Pro v4.5 Recon and Nomad Reference Manual User Manual
Page 152
Survey Pro Reference Manual
R-144
Video Scan Settings
Survey Video Scan
The Video Scan Settings screen is used to configure how many points
to shoot within the scan frame. You have a choice to define the
number of points by distance between points, angle between points,
total number of points, or the time required to shoot all points.
By Distance HD/VD: specifies the horizontal and vertical
distances between points that are measured within a
scan frame.
At Distance: is the distance from the total station to the
surface to be scanned.
Shoot : Tap this to measure a new distance for the At
Distance
field.
By Angle HA/VA: specifies the horizontal and vertical
angles the total station will turn to advance to each point
within a scan frame.
By Points in Total: is the number of points to shoot
within the scan frame.
By Time Estimate: will shoot the number of evenly
spaced points within the scan frame to finish
approximately in the time entered here.
Recalculate : This will recalculate the remaining value(s) in any
dependent fields after changes are made.
Automatic Image Capture of Scan Frame: When checked,
panoramic photographs within the scan frame are automatically
taken after a video scan is performed for viewing within RealWorks
along with the video scan data.