beautypg.com

Measure mode settings – Spectra Precision Survey Pro v4.5 Recon and Nomad Reference Manual User Manual

Page 110

background image

Survey Pro Reference Manual

R-102

Measure Mode Settings

Job Settings Measure Mode

.

The Measure Mode card is used to configure the RTK data collection

settings.

Receiver Dynamics

: is where you control the receiver

dynamics for point occupations. There are two choices

Static on occupy: On starting a point

occupation, receiver is put in static mode where

it calculates position assuming no motion and
applies advanced averaging techniques for the

most precise solution.

Dynamic always: Receiver is left in dynamic

mode for all point occupations.

Accept Solution Quality

: is where you control the

solution quality acceptable for storing measurements.

You have two options:

Fixed RTK only: Allows storage of fixed solution

only.

Code, Float, or Fix: Allows storage of any differential

solution.

Use Acceptance Criteria

: is where you select to apply criteria to

measurement acceptance. When checked, only measurements with
RMS

and/or PDOP values below the threshold will be accepted. To

use less than all three criteria, check this box but enter 0.0 for the
criteria you do not wish to apply.

H RMS: is the horizontal RMS threshold for automatic

acceptance or warning on point acceptance.

V RMS: is the vertical RMS threshold for automatic

acceptance or warning on point acceptance.

PDOP: is the PDOP threshold for automatic acceptance or

warning on point acceptance.

Automatically Accept Data Collection:

is where you select to