Survey Pro Reference Manual

R-104

Post Process Settings

Job Settings Post Process or

Connect to Receiver Receiver Settings

The Post Process card is used to configure the settings for logging

post processing data, and the collecting and storing of post processing

points in Survey Pro.

Recording Interval

: is where you set the period for

logging GPS raw data for post processing. Set it to Off to
disable post processing data collection in Survey Pro.

RTK Autonomous Points:

is where you specify action to

take when accepting autonomous points during RTK

data collection. There are three options.

Do not store: this option will prohibit acceptance

of autonomous points in RTK data collection
routines.

Prompt for layer: this option will prompt the

user whenever an autonomous point is accepted.

The layer specified will be the default layer to

store autonomous points, but the user can over
ride at the prompt.

Store on selected layer: this option will automatically store

autonomous points accepted during RTK data collection
routines on the specified layer.

Layer

: displays the layer selected to store autonomous points.

Select Layer : opens up a layer prompt to allow you to select an

existing layer or create a new layer to store autonomous points.

Session Monitor

: is where you select to use the session monitoring

thresholds when collecting data with the Static / Rover Session

screen. To have Survey Pro display warnings during post processing

data collection, check Warn me if, and specify threshold values for the
number of SV, HDOP and memory.